IP65 Report:Water resistance:IP-X5,Dust resistance:IP-6X
a.Inner Nozzle diameter:6.3mm;
b. Water speed:12.5±0.625L/min;
c. Water Pressure:adjust according to water volumn;
d.Central part of water volumn
e.Spray time in surface of panel:about 1min;
f.Test time:at least 3min;
g.Distance between nozzle and panel surface:2.5~3m.
After test,there is no water leakage in sample.